MM-400A - Analizzatore di saldature desktop
Key Features MM-400A - Desktop Resistance Weld Checker
- Measures Current, Force, Voltage, Time and displacement
- Envelope function
- Seam welding mode
- ISO17657 compliant measurement for current
- Built-in printer
- RS232/485 output
- Multi-language support
Specifications MM-400A - Analizzatore di saldature desktop
Modello | 3-400-01 (Basic) 3-400-02 (Force and displacement) |
---|---|
Current range | 1x sensitivity toroidal coil~0.100~2.000 kA/0.30~6.00 kA/1.00~20.00 kA/3.0~60.0 kA/10.0~200.0 kA (MB-400 M/800 M) 10x sensitivity toroidal coil~0.01~0.2 kA/0.03~0.6 kA/0.1~2.0 kA/0.3~6.0 kA/1.0~20.0 kA (MB-45F) Shunt resistor~0.025 kA~0.5 kA/0.05~1.0 kA |
Misurazione corrente | PEAK/RMS*2 / Arithmetic mean RMS. Accuracy ±1% Full scale |
Voltage range | 0.30~6.00 V/1.0~20.0 V. Accuracy ±1% Full scale |
Misurazione tensione | PEAK/RMS*2 / Arithmetic mean RMS. Accuracy ±1% Full scale |
Displacement Range *1 | When the SENSOR STEP setting is 1 μm: ±30.000 mm. Accuracy ±30.000 mm range: ±15 μm (sensor with 1 μm or less resolution) When the SENSOR STEP setting is 10 μm: ±300.00 mm. Accuracy ±300.00 mm range: ±150 μm (sensor with 10 μm or less resolution) |
Displacement measurement *1 | Before welding / After welding / Constant |
Force Range *1 | 0.49~98.06 N (MA-520) / 0.49~980.6 N (MA-521) / 245~4903 N (MA-770) ±3% Full scale |
Force measurement *1 | Mean RMS / maximum (peak) Before welding / After welding / Constant. Accuracy ±3% Full scale |
Force input voltage / current range *1 | -10 to +10V / 4 to 20 mA |
External range | 5% to 100% of rated setting |
External measurement | Mean RMS/maximum (peak) Before welding / After welding / Constant. Accuracy ±3% Full scale |
Measurement time current voltage displacement power resistance AC ms-AC | 1 to 5000 ms |
Measurement time current voltage displacement power resistance AC CYC-AC | 0.5 to 250.0 CYC (50 Hz) 0.5 to 300.0 CYC (60 Hz) |
Measurement time current voltage displacement power resistance AC CYC***HZ-AC | 0.5 to 200.0 CYC (M050 : 50Hz) 0.5 to 300.0CYC (M063 : 63 Hz) 0.5 to 2000.0 CYC (M500 : 500 Hz) |
Measurement time current voltage displacement power resistance AC LONG CYC-AC | 0.5 to 500.0 CYC (50 Hz) 0.5 to 600.0 CYC (60 Hz) |
Measurement time Current Voltage Displacement Power Resistance DC CYC-DC | 0.5 to 100.0 CYC (50 Hz) 0.5 to 120.0 CYC (60 Hz) |
Measurement time Current Voltage Displacement Power Resistance DC ms-DC | 1 to 2000 ms |
Measurement time Current Voltage Displacement Power Resistance DC SHORT ms-DC | 0.50 to 100.00 ms (0.05 ms increment) |
Measurement time force external | 1 to 10000 ms |
Angolo di conduzione | 0 to 180 degrees. Accuracy ±9 degrees |
Units | V / N / kgf / lbf / ºF / Mpa / bar / psi |
Potenza di ingresso | Single-phase 100 to 240 VAC±10% (50/60 Hz) or 24 VDC+/-10% |
External data output | RS-232C/RS-485/Ethernet |
Lingue | Japanese, English, Chinese, Korean, German, French, Spanish |
No. of schedules | 127 |
Power usage | 41 W (49 W with printer running) |
*1 | Force and displacement model only |
MASSA E DIMENSIONI | |
Dimensioni (LxPxA) | 290 mm x 172 mm x 269 mm (31.2 in x 17.4 in x 33.9 in (excluding protrusions)) |
Massa | Approx. 5 kg (11 lb) |