The MEA-100B - AC Resistance Welding Power Supply is perfectly suited for the precision resistance welding of small-sized components. This high performance AC resistance welding power supply capable of delivering up to 8,000 A output. It offers an intuitive user interface for easy operation, combined with a compact, desktop footprint.
Model | MEA-100B AC Resistance Power Supply | |
---|---|---|
Power requirements | Single phase, 200/220/230/240/380/400/460/480VAC +13% -20%, 50/60Hz (Voltage is selectable but factory-fixed on shipment) | |
Max. capacity | 20kVA (10% @200VAC), 26kVA (10% @400VAC), 31kVA (10% @480VAC) | |
Control modes | 1) Secondary constant current control 2) Power-supply voltage compensation contro | |
Welding mode | 1) Multiple cycle, 2) Single cycle, 3) Half cycle | |
Control speed | Half cycle | |
Welding current accuracy | @ Secondary constant-current control (when the current is set to the maximum value) Supply voltage fluctuation Resistance load fluctuation*) } within ± 2% for a fluctuation of ± 10% Inductive load fluctuation*) *) Fluctuation from our standard load. | |
Timer setting | @ Multiple cycle mode | @ Multiple cycle mode Initial force apply, Weld 1, Cool, Weld 2, Hold 0 – 99 cycles Upslope 1, Upslope 2, Down slope 0 – 9 cycles Pulsation 1 – 9 times |
Timer setting range: Squeeze delay | @ Single cycle mode | Initial force apply, Hold 0 – 99 cycles, First half wave/Second half wave 0.5 cycles |
Timer setting | @ Half cycle mode | Initial force apply, Hold 0 – 99 cycles, Half wave 0.5 cycles |
Current setting range | @ Secondary constant current control mod | Current 1, Current 2 0.20 – 9.99kA (by 0.01kA) |
Current setting range | @ Power-supply voltage compensation control mode | Current 1, Current 2 0.0 – 99.9% (by 0.1%) |
Current monitoring | @ Secondary constant current control mode | Upper limit setting: +1 - +49% Lower limit setting: -1 – -49% |
Current monitoring | @ Power-supply voltage compensation control mode | Upper limit setting: 0.01 – 9.99kA (by 0.01kA) Lower limit setting: 0.01 – 9.99kA ‘by 0.01kA) |
Option | MB-400K Toriodal coil (required at secondary constant current control) | |
External communication | RS-482, bi-directional communication | |
Operating environment | Temperature: 0 – 45 degree C, Humidity: 90% or below (No condensation) | |
Power consumption | 15W or less in stand-by | |
Global standards | CE and CCC Certified | |
WEIGHT & DIMENSIONS | . | |
Dimensions (LxWxH) | 418 mm x 142 mm x 269 mm (16.4 in x 5.6 in x 10.6 in) | |
Weight | 6.5 kg (14.3 lb) |