Commutator fusing
The IS-300A - Inverter Spot Welder is small enough to fit on a bench, which is ideal for customers and integrators who require high output, but have limited production space.
The IS-300A - Inverter Spot Welder offers a range of new and improved features including six control modes (primary limit, primary and secondary root mean square (RMS), secondary constant power, secondary voltage control, and fixed pulse) and 0.050 kA - 20 kA of power in 3 ranges. The low current ranges are ideal for small or fine applications.
Model | IS-300A-00-00 | IS-300A-00-01 |
---|---|---|
Power requirements (fixed at factory) | 3-phase, 200-240 VAC ±10% (50/60 Hz) | 3-phase, 380–480 VAC ±10% (50/60Hz) |
Max. output current | 300 A (peak value) | 300 A (peak value) |
Duty cycle | 300 A @ 4.4% 200 A @ 10%, 100 A @ 35%, 45 A @ 100% | 300 A @ 4.4% 200 A @ 10%, 100 A @ 35%, 45 A @ 100% |
Number of schedules | 255 | 255 |
Output frequency | 600 Hz~3 kHz (in 100 Hz increments) | 600 Hz~3 kHz (in 100 Hz increments) |
Control method | Primary constant-current RMS / Secondary constant-current RMS / Secondary constant-power RMS / primary constant-current PEAK / Secondary constant-voltage RMS / Constant-phase control | Primary constant-current RMS / Secondary constant-current RMS / Secondary constant-power RMS / primary constant-current PEAK / Secondary constant-voltage RMS / Constant-phase control |
Timer setting range | Millisecond mode | Cycle mode |
Timer setting range: Squeeze delay | 0000~9999 ms | 000~999 cyc |
Timer setting range: Squeeze | 0000~9999 ms | 000~999 cyc |
Timer setting range: Up-Slope 1,2,3 | 000~999 ms | 00~50 ms |
Timer setting range: Weld 1, 2, 3 | 000~999 ms | 00~50 ms |
Timer setting range: Down-Slope 1,2,3 | 000~999 ms | 00~50 ms |
Timer setting range: Cool 1,2 | 000~999 ms | 000~999 ms |
Timer setting range: Hold | 0000~20000 ms | 000~999 ms |
Timer setting range: Off | 0 or 10~9990 ms | 00~99 ms |
Transformer turns ration | 1.0~199.9 | 1.0~199.9 |
Pulsation setting | 01~19 | 01~19 |
Valve setting | 2 | 2 |
Setting range: Constant current | 0.05~ 20.0 kA | 0.05~ 20.0 kA |
Setting range: Constant power | .05~20.0 kW | .05~20.0 kW |
Setting range: Constant voltage | 0.20~9.99 V | 0.20~9.99 V |
Setting range: Constant Phase | 10.0~99.9% | 10.0~99.9% |
Current monitor | 00.0~99.9 kA / 0.00~9.99 kA | 00.0~99.9 kA / 0.00~9.99 kA |
Power monitor | 000.0~999.9 kW / 00.00~99.99 kW | 000.0~999.9 kW / 00.00~99.99 kW |
Voltage monitor | 0.00~9.99 V | 0.00~9.99 V |
Pulse width monitor | HIGH 10.0~100% | HIGH 10.0~100% |
Cooling method | Forced air cooling | Forced air cooling |
Data communication | RS-232C (one-way communication) / RS-485 (bidirectional communication) | RS-232C (one-way communication) / RS-485 (bidirectional communication) |
Corresponding transformer | IT-1040-3 | (500 V) IT-4040-3 IT-4085-3, IT-4140-3 (650 V) IT-1040-3, IT-1085-3, IT-1140-3 |
Dimensions (LxWxH) | 574.0 mm x 172.7 mm x 269.2 mm 22.6 (in x 6.8 in x 10.6 in) | 574.0 mm x 172.7 mm x 269.2 mm 22.6 (in x 6.8 in x 10.6 in) |
Weight | 16.5 kg (36.4 lbs) | 16.5 kg (36.4 lbs) |
Send your sample to one of our technology centers in Europe for an evaluation. We will then determine which solution meets your needs best. AMADA WELD TECH offers feasibility testing and application consulting.