Vous êtes ici

Série IS-Q - Alimentation électrique par onduleur (anciennement connu sous le nom de Serié ISQ )

The IS-Q Series - Inverter Power Supply is designed to be used in combination with mechanical, pneumatical or motorised weld heads. It offers process control monitoring with MG3 and with the OP-AWS3-A Active Welding System. The OP-AWS3-A integrates the process control of all mechanical and electrical parameters, static and dynamic process monitoring, quality analysis with advanced SPC feature and datalogging.

Key features IS-Q Series - Inverter Power Supply

  • Compact design for optimal system integration
  • Integrated process monitoring allows for quality control
  • Short cycle times thanks to high output current
  • Up to 20 kHz feedback for fast reaction to fluctuations in the weld process
  • Optimum feedback thanks to current, voltage and power mode controls
  • Additional force control via proportional valve
. IS-Q3000AIS-Q6000AIS-Q250AIS-Q500A
Performance range 0,75 kA – 1,5 kA - 3 kA6 kA10 kA20 kA
Types de courant de soudage Controlled DC inverter currentControlled DC inverter currentAC or DC inverter
Caractéristiques Inverter with integrated power on button, Performance and Control Electronics, Voltage control cable und removable Display MFT1 (optional: AWS3-Display) and additional: compact version w/integrated transformer, voltage sensor cableInverter with integrated power on button, Performance and Control Electronics, Voltage control cable und removable Display MFT1 (optional: AWS3-Display) and additional: Compact version w/integrated transformer, voltage sensor cableInverter with integrated power on button, Performance and Control Electronics, Voltage control cable und removable Display MFT1 (optional: AWS3-Display) and additional: Separate DC- or AC- transformerInverter with integrated power on button, Performance and Control Electronics, Voltage control cable und removable Display MFT1 (optional: AWS3-Display) and additional: Separate DC- or AC- transformer, external main fuse and net filter
Options 19“ plug-in unit without main unit19“ plug-in unit ithout main unit19“ plug-in unit without main unit19“ plug-in unit without main unit
Mode de contrôle / contrôle Current, voltage or power feedback control, independently adjustable independently for each pulse, APC (Active Part Conditioner) function and current, voltage, performance and energy limitsCurrent, voltage or power feedback control, independently adjustable independently for each pulse, APC (Active Part Conditioner) function and current, voltage, performance and energy limitsCurrent, voltage or power feedback control, independently adjustable independently for each pulse, APC (Active Part Conditioner) function and current, voltage, performance and energy limitsCurrent, voltage or power feedback control, independently adjustable independently for each pulse, APC (Active Part Conditioner) function and current, voltage, performance and energy limits
Programmes de soudage programmables / sélection de programmes de soudage externe 99 at single axis; 49 per head at dual axis 99 at single axis; 49 per head at dual axis 99 at single axis; 49 per head at dual axis 99 at single axis; 49 per head at dual axis
Nombre d'impulsions de soudage 1st and/or 2nd pulse, 2nd pulse can be repeated max 10 times (decrease adjustable down to 1% of 2nd pulse)1st and/or 2nd pulse, 2nd pulse can be repeated max 10 times (decrease adjustable down to 1% of 2nd pulse)1st and/or 2nd pulse, 2nd pulse can be repeated max 10 times (decrease adjustable down to 1% of 2nd pulse)1st and/or 2nd pulse, 2nd pulse can be repeated max 10 times (decrease adjustable down to 1% of 2nd pulse)
Contrôle des impulsions de soudage Up slope, weld-time, down-slope, break time, impuls cycleUp slope, weld-time, down-slope, break time, impuls cycleUp slope, weld-time, down-slope, break time, impuls cycleUp slope, weld-time, down-slope, break time, impuls cycle
Mesure du courant Integrated toroidal coil (Rogowski coil)Integrated toroidal coil (Rogowski coil)external toroidal coil external toroidal coil
Mesure de la tension Potential free, external connection (X10 axis/head 1; X11 axis/head 2)Potential free, external connection (X10 axis/head 1; X11 axis/head 2)Potential free, external connection (X10 axis/head 1; X11 axis/head 2)Potential free, external connection (X10 axis/head 1; X11 axis/head 2)
Limit values Display with limit exceeding upper and lower limit, time limit, welding energy limit with sensitive components (weld to limit)Display with limit exceeding upper and lower limit, time limit, welding energy limit with sensitive components (weld to limit)Display with limit exceeding upper and lower limit, time limit, welding energy limit with sensitive components (weld to limit)Display with limit exceeding upper and lower limit, time limit, welding energy limit with sensitive components (weld to limit)
Out of limit error message Text indication with limit and device errors; monitoring limits for U, I or P; + and – tolerance windows individually adjustableText indication with limit and device errors; monitoring limits for U, I or P; + and – tolerance windows individually adjustableText indication with limit and device errors; monitoring limits for U, I or P; + and – tolerance windows individually adjustableText indication with limit and device errors; monitoring limits for U, I or P; + and – tolerance windows individually adjustable
Parts check Test pulse for part detection (pre-weld-check)Test pulse for part detection (pre-weld-check)Test pulse for part detection (pre-weld-check)Test pulse for part detection (pre-weld-check)
Opération One button toggle wheel, monochrome display, Optional: coloured OP-AWS3-A Display, Profibus or Ethernet IPOne button toggle wheel, monochrome display, Optional: coloured OP-AWS3-A Display, Profibus or Ethernet IPOne button toggle wheel, monochrome display, Optional: coloured OP-AWS3-A Display, Profibus or Ethernet IPOne button toggle wheel, monochrome display, Optional: coloured OP-AWS3-A Display, Profibus or Ethernet IP
Certification UE CE CompliantCE CompliantCE CompliantCE Compliant
Continuous sound pressure level The equivalent continuous sound pressure level rated A is below 70 dB. Sound pressure levels may vary depending on the welding material and the environmental conditions. If necessary consult an acoustic specialist.The equivalent continuous sound pressure level rated A is below 70 dB. Sound pressure levels may vary depending on the welding material and the environmental conditions. If necessary consult an acoustic specialist.The equivalent continuous sound pressure level rated A is below 70 dB. Sound pressure levels may vary depending on the welding material and the environmental conditions. If necessary consult an acoustic specialist.The equivalent continuous sound pressure level rated A is below 70 dB. Sound pressure levels may vary depending on the welding material and the environmental conditions. If necessary consult an acoustic specialist.
Electrical data
Tension d'alimentation 3x 400 VAC, ± 10%, PE; 3x 230 V (optional), ISQ20-MFC 19 ± 10%, PE : non-heating, 3 pole connector3x 400 VAC, ± 10%, PE; 3x 230 V (optional), ± 10%, PE ISQ20-MFC 19”: non-heating, 3 pole connector3x 400 VAC, ± 10%, PE3x 400 VAC, ± 10%, PE
Fréquence secteur 50 - 60 Hz50 - 60 Hz50 - 60 Hz50 - 60 Hz
Fusion with 400 V: 3x 16 A, delayed; with 230 V (optional): 3x 32A, delayedwith 400 V: 3x 16 A, delayed; with 230 V (optional): 3x 32A, delayed3 x 32A, delayed3 x 125A, delayed (external)
Câble de connexion with 400 V: 4 x 2.5 mm², with 230 V (optional): 4 x 4 mm²with 400 V: 4 x 2.5 mm², with 230 V (optional): 4 x 4 mm²4 x 6 mm²4 x 50 mm² shielded
Classe de protection IP30 ISQ20-MFC 19“: depending on housingIP30 ISQ20-MFC 19“: depending on housingIP30 ISQ20-MFC 19“: depending on housingIP30 ISQ20-MFC 19“: depending on housing
Welding transformer internal for 3 kAinternal for 6 kAExternal DC: IT-60X AC: TRM3 14-9 V MT40X-530External: DC: IT-113 AC: upon request
Power data IS-Q3000AIS-Q6000AIS-Q250AIS-Q500A
Connected load 11 kVA11 kVA22 kVA85 kVA
Switching frequency max. 20 kHzmax. 14 kHz1 – 10 kHz (AC) 1 – 5 kHz (DC) depending on primary current1 – 10 kHz (AC) 1 – 5 kHz (DC) depending on primary current
Fréquence de sortie 40 kHz26 kHz1 – 10 kHz (AC) 2 – 10 kHz (DC)1 – 10 kHz (AC) 2 – 10 kHz (DC)
Fundamental frequency AC ------AC: 50 – 250 HzAC: 50 – 250 Hz
Rated power 12 kVA24 kVA40 kVA (DC)25 kVA (AC), DC with IT 113: 75 kVA; dep on transformer
Courant de soudage maxi 3 kA with 5% d.r.6 kA with 5% d.r.10 kA with 8% d.r. DC only20 kA with 15% d.r. DC only
Max. weld period 320 ms/pulse320 ms/pulse640 ms/pulse320 ms/pulse
Min. weld period 0.7 ms0.7 msDC: 0,7 ms AC: 0,5 x impuls frequencyDC: 0,7 ms AC: 0,5 x impuls frequency
Rated output current 2 kA 11% d.r.3 kA 20% d.r.depending on transformerdepending on transformer
Min. terminal voltage 4 V with 3 kA4 V with 6 kADC: 4 V with 10 kA AC: dep on transformerDC with IT 113: 3 V at 25 kA; AC: dep on transformer
Max. open-circuit voltage 10 V10 VDC: 10 V AC: dep on transformerDC: 11 V AC: dep on transformer
Interface
Secondary connections CU-rails, 2 x M8 internal threadCU-rails, 2 x M8 internal threadDepending on transformerDepending on transformer
Entrée analogique Pressure sensor for proportional valvePressure sensor for proportional valvePressure sensor for proportional valvePressure sensor for proportional valve
Sortie analogique Proportional valve controlProportional valve controlProportional valve controlProportional valve control
Interfaces numériques via D-Sub-9 socket; welding data output in ASCII-compatible printing formatvia D-Sub-9 socket; welding data output in ASCII-compatible printing formatvia D-Sub-9 socket; welding data output in ASCII-compatible printing formatvia D-Sub-9 socket; welding data output in ASCII-compatible printing format
Entrée d'interface binaire Start, quick stop, pressure switch, proximity switches, pressure sensorStart, quick stop, pressure switch, proximity switches, pressure sensorStart, quick stop, pressure switch, proximity switches, pressure sensorStart, quick stop, pressure switch, proximity switches, pressure sensor
Sortie d'interface binaire a.o. stepping contact, counter, set point deviation, closing stroke, welding pressure, air valvesa.o. stepping contact, counter, set point deviation, closing stroke, welding pressure, air valvesa.o. stepping contact, counter, set point deviation, closing stroke, welding pressure, air valvesa.o. stepping contact, counter, set point deviation, closing stroke, welding pressure, air valves
Opération
Refroidissement Forced air ventilation, temperature controlledForced air ventilation, temperature controlledTransformer water cooledInverter and transformer water cooled
Moisture 40 - 70 %, not condensating40 - 70 %, not condensating40 - 70 %, not condensating40 - 70 %, not condensating
Ambient Temperature 0 - 40°C0 - 40°C0 - 40°C0 - 40°C
. IS-Q3000AIS-Q6000AIS-Q250AIS-Q500A
Weight inverter approx 33 kgapprox 43 kgapprox 20 kg (without transforner)approx 31 kg (without transforner etc)
Dimensions inverter (BxHxW) 216 x 420 x 480 mm 216 x 420 x 550 mm (including projection) ISQ20-MFC-19": 482 x 174 x 315 mm216 x 420 x 480 mm 216 x 420 x 550 mm (including projection) ISQ20-MFC-19": 482 x 174 x 315 mm216 x 420 x 480 mm 216 x 420 x 550 mm (including projection) ISQ20-MFC-19": 482 x 174 x 315 mm216 x 420 x 480 mm 216 x 420 x 550 mm (including projection) ISQ20-MFC-19": 482 x 174 x 315 mm
Weight transformer ------IT-60X: approx 16 kg TRM3: approx 45 kg MT-40X-530: approx 63 kgIT-113: approx 25,5 kg
Dimensions transformer (BxHxW) in mm ------TRM3: 360 x 150 x 185 IT-60X: 284 x 110 x 170 MT-40X-530: 732 x 92 x235IT-113: 420 x 125 x 230
Stranded wire to Coil
Motor Fusing
Stranded wire to terminal

Solutions personnalisées

Envoyez votre échantillon à un de nos centres technologiques en Europe pour une expertise. Nous déterminerons ensuite la meilleure solution pour répondre à vos besoins. AMADA WELD TECH propose des tests de faisabilité et des conseils d’application.

Contactez-nous