AMADA WELD TECH bietet eine Vielzahl von AC-Steuerungen, die speziell auf die Bedürfnisse der einzelnen Anwendungen zugeschnitten sind. Wechselstromquellen (AC) mit Phasenwinkelsteuerung sind meist die günstigste Alternative zu anderen Technologien.
Kriterien | M2L | M2P | M4L | M4P |
---|---|---|---|---|
Konfigurationshardware | Compact Tower AC power supply for external welding transformers; with integrated power stage | Compact Tower AC power supply for external welding transformers; with integrated power stage | Compact 19" flat AC Power supply with air control unit, without main stage | Compact 19" flat AC Power supply with air control unit, without main stage |
Sondermerkmale | M2P and M4P are equipped with external program selection and proportional valve control | M2P and M4P are equipped with external program selection and proportional valve control | M2P and M4P are equipped with external program selection and proportional valve control | M2P and M4P are equipped with external program selection and proportional valve control |
Allgemeine Optionen | Cycle control unit; 3-point electrodes for Insulated wire welding, other voltages; external weld schedules with 99 programs via BCD selection | Cycle control unit; 3-point electrodes for Insulated wire welding, other voltages; external weld schedules with 99 programs via BCD selection | Cycle control unit; 3-point electrodes for Insulated wire welding, other voltages; external weld schedules with 99 programs via BCD selection | Cycle control unit; 3-point electrodes for Insulated wire welding, other voltages; external weld schedules with 99 programs via BCD selection |
Sonderoptionen | . | . | Integral air cassette C40 (M4L) or CPV (M4P) | Integral air cassette C40 (M4L) or CPV (M4P) |
Versorgungsspannung | 400 V AC +/3 10% (440/480 V optional for M4L and M4P) | 400 V AC +/3 10% (440/480 V optional for M4L and M4P) | 400 V AC +/3 10% (440/480 V optional for M4L and M4P) | 400 V AC +/3 10% (440/480 V optional for M4L and M4P) |
Hauptfrequenz | 50-60 Hz | 50-60 Hz | 50-60 Hz | 50-60 Hz |
Anschlussnennwert | 4.5 kVA (with TRM3 transformer) | 4.5 kVA (with TRM3 transformer) | Depends on transformer | Depends on transformer |
Verschmelzen | 25/20A delayed | 25/20A delayed | Depends on transformer | Depends on transformer |
Schutzklasse | IP30 | IP30 | IP30 | IP30 |
Schweißspannung | Depends on connected transformer | Depends on connected transformer | Depends on connected transformer | Depends on connected transformer |
Leerlaufspannung | Variable via 8-step switch, Vmax is dependent on connected transformer | Variable via 8-step switch, Vmax is dependent on connected transformer | Depends on transformer | Depends on transformer |
Nennleistung | Depends on connected transformer; max 15 kVA at 50% d.r. | Depends on connected transformer; max 15 kVA at 50% d.r. | Depends on transformer | Depends on transformer |
Max. Nennleistung | Depends on transformer max 80 kVA | Depends on transformer max 80 kVA | Depends on transformer | Depends on transformer |
Max. Schweißstrom | Depends on connected transformer | Depends on connected transformer | Depends on connected transformer | Depends on connected transformer |
Sequence control | For weld head with stroke cylinder or for weld pincers as an option. | For weld head with stroke cylinder or for weld pincers as an option. | For weld head with stroke cylinder or for weld pincers as an option. | For weld head with stroke cylinder or for weld pincers as an option. |
Steuerung / Steuermodus | Via phase angle with secondary voltage stepping switch | Via phase angle with secondary voltage stepping switch | Via phase angle with secondary voltage stepping switch | Via phase angle with secondary voltage stepping switch |
Schweißkopfsteuerung | Variable hold, rest and repeat times; as selected via air or proportional valve, with closing and welding pressure | Variable hold, rest and repeat times; as selected via air or proportional valve, with closing and welding pressure | Variable hold, rest and repeat times; as selected via air or proportional valve, with closing and welding pressure | Variable hold, rest and repeat times; as selected via air or proportional valve, with closing and welding pressure |
Programmierbare und externe Schweißpläne | 99 | 99 | 99 | 99 |
Anzahl der Schweißimpulse | 2 programmable pulses | 2 programmable pulses | 2 programmable pulses | 2 programmable pulses |
Schweißimpulssteuerung | Closing time, squeeze time, up-slope, on-time, down-slope | Closing time, squeeze time, up-slope, on-time, down-slope | Closing time, squeeze time, up-slope, on-time, down-slope | Closing time, squeeze time, up-slope, on-time, down-slope |
Wiederholbarkeit 2. Schweißimpuls | Max. 99 | Max. 99 | Max. 99 | Max. 99 |
Weld transformer | TRM3 | TRM3 | TRM1, TRM3, TRM4 or TR5 | TRM1, TRM3, TRM4 or TR5 |
Analogein- und -ausgang | M2L, M4L: none; M2P, M4P, Pressure sensor for proportional valve | M2L, M4L: none; M2P, M4P, Pressure sensor for proportional valve | M2L, M4L: none; M2P, M4P, Pressure sensor for proportional valve | M2L, M4L: none; M2P, M4P, Pressure sensor for proportional valve |
Binärer Schnittstelleneingang | Start 1 to 3, quick-stop, without current | Start 1 to 3, quick-stop, without current | Start 1 to 3, quick-stop, without current | Start 1 to 3, quick-stop, without current |
Binärer Schnittstellenausgang | Stepping contact; ready; air valve 1 to 3; locking contact; BSD selection (M2P and MP4P only) | Stepping contact; ready; air valve 1 to 3; locking contact; BSD selection (M2P and MP4P only) | Stepping contact; ready; air valve 1 to 3; locking contact; BSD selection (M2P and MP4P only) | Stepping contact; ready; air valve 1 to 3; locking contact; BSD selection (M2P and MP4P only) |
Umgebungstemp. | 0-40 °C | 0-40 °C | 0-40 °C | 0-40 °C |
Kühlung | Water-cooled (2L/min at 3 bar) | Water-cooled (2L/min at 3 bar) | Air-cooled | Air-cooled |
Gesetzliche Genehmigung | CE compliant | CE compliant | CE compliant | CE compliant |
Gewicht | Approx. 30 kg | Approx. 30 kg | Approx. 7.5 kg | Approx. 7.5 kg |
Abmessungen (L x H x T) | 220 x 420 x 570 mm | 220 x 420 x 570 mm | 450 x 135 x 335 mm | 450 x 135 x 335 mm |